The PURCEREAL
nitrogen generator is used mainly in disinfestation of cereals but also
with other stored products. It is connected rapidly to silos containing
the product to be treated and into wich inert gas is to be pumped with
the aim of disinsect cereals from any kind of insect at any stage of developement.
PURCEREAL is attached to a methane gas network (but can also operate with
propane or butane) wich is them mixed with equal quantities of air and
then pumped into a combustion chambre and burned. The inert gas thus created
comprises 86% nitrogen, approximately 13-14% carbon dioxide and 1% oxigen;
it is pumped into the silos from below and at the same time an electronic
analyser monitors gas concentrations so as to create a totally aseptic
atmosphere within the silo.
|
|
The equipment
is equipped with all safety systems required for gas plants (blocking
systems in absence of gas, cooling water etc.) and a drying system for
the generated gas.
ADVANTAGES
- rapid
transformation of the atmosphere in the storage containers and therefore
ability to produce large quantities of gas at low cost;
- absence
of negative effects on the treated product; inert gas in fact is neither
toxic not flammable and therefore does non interfere with the biological
and nutritional characteristics of the product.
|
|
 |
|
|
Model
|
|
Purcer
60
|
Purcer
100
|
Purcer
150
|
Purcer
200
|
|
Total
mass
|
kg
|
390
|
480
|
1000
|
1200
|
|
Max
depth
|
mm
|
1500
|
1500
|
1280
|
1280
|
|
Max
width
|
mm
|
1200
|
1200
|
1820
|
1820
|
|
MAx
height
|
mm
|
1600
|
1600
|
1980
|
1980
|
|
Propane
consumption
|
kg/h
|
5
|
8
|
12
|
16
|
|
Methane
consumption
|
kg/h
|
4
|
7
|
10
|
14
|
|
Cooling
water capacity at inlet
|
mc/h
|
2,3
|
2,3
|
4,0
|
4,0
|
|
Cooling
water pressure at inlet
|
bar
|
2,5
|
2,5
|
4,0
|
4,0
|
|
Quality
of air produced
|
Nmc/h
|
60
|
100
|
150
|
200
|
|
Composition
of gas produced
|
vol.%
di CO2
|
13
|
13
|
13
|
13
|
|
Composition
of gas produced
|
vol.%
di O2
|
1
|
1
|
1
|
1
|
|
Composition
of gas produced
|
vol.%
di CO
|
0,001
|
0,001
|
0,001
|
0,001
|
|
Composition
of gas produced
|
vol.%
di N2
|
86
|
86
|
86
|
86
|
|
Power
absorption
|
Kw
|
5,5
|
8
|
12
|
16
|
|
Electric
characteristics
|
-
|
380V
- 50 Hz - 3 fasi + N +T
|
|
Protection
of the electric system and control system
|
-
|
IP
44
|
|
Room
temperature
|
-
|
min.
5 °C - max 35 °C
|
|
|